Showing posts with label GATE. Show all posts
Showing posts with label GATE. Show all posts

Thursday, 21 February 2013

Instrumentation and Measurement Objection Question book bank


  
(1) Instrument is a device for determining
(a) the magnitude of a quantity
(b) the physics of a variable
(c) either of the above
(d) both (a) and (b)
(2) Electronic instruments are preferred because they have
(a) no indicating part
(b) low resistance in parallel circuit
(c) very fast response
(d) high resistance in series circuit
(e) no passive elements.
(3) A DC wattmeter essentially consist of
(a) two ammeters
(b) two voltmeters
(c) a voltmeter and an ammeter
(d) a current and potential transformer
(4) Decibel is a unit of
(a) power
(b) impedance
(c) frequency
(d) power ratio
(5) A dc voltmeter may be used directly to measure
(a) frequency
(b) polarity
(c) power factor
(d)power
(6) An accurate voltmeter must have an internal impedance of
(a) very low value
(b) low value
(c) medium value
(d) very high value
(7) The insulation resistance of a transformer winding can be easily measured with
(a) Wheatstone bridge
(b) megger
(c) Kelvin bridge
(d) voltmeter
(8) A 100 V voltmeter has full-scale accuracy of 5%. At its reading of 50 V it will give an error of
(a) 10%
(b) 5%
(c) 2.5%
(d) 1.25%
(9) You are required to check the p. f. of an electric load. No p.f. meter is available. You would use:
(a) a wattmeter
(b) a ammeter, a voltmeter and a wattmeter
(c) a voltmeter and a ammeter
(d) a kWh meter
(10) The resistance of a field coil may be correctly measured by using
(a) a voltmeter and an ammeter
(b) Schering bridge
(c) a Kelvin double bridge
(d) a Maxwell bridge
(11) An analog instrument has output
(a) Pulsating in nature
(b) Sinusoidal in nature
(c) Which is continuous function of time and bears a constant relation to its input
(d) Independent of the input quantity
(12) Basic charge measuring instrument is
(a) Duddel's oscillograph
(b) Cathode ray oscillograph
(c) Vibration Galvanometer
(d) Bailastic Galvanometer
(e) Battery Charging equipment
(13) A.C. voltage can be measured (using a d.c. instrument) as a value obtained
(a) by subtracting the d.c. reading from it's a.c. reading.
(b) Using the output function of the multimeter
(c) By using a suitable inductor in series with it
(d) By using a parallel capacitor with it
(e) None of the above
(14) A moving coil permanent magnet ammeter can be used to measure
(a) D. C. current only
(b) A. C. current only
(c) A. C. and D. C. currents
(d) voltage by incorporating a shunt resistance
(e) none of these
(15) Select the wrong statement
(a) the internal resistance of the voltmeter must be high
(b) the internal resistance of ammeter must be low
(c) the poor overload capacity is the main disadvantage of hot wires instrument
(d) the check continuity with multimeter, the highest range should be used.
(e) In moving iron voltmeter, frequency compensation is achieved by connecting a capacitor across its fixed coil.
(16) Which of the following instrument is suitable for measuring both a.c. and d.c.
quantities.
(a) permanent magnet moving coil ammeter.
(b) Induction type ammeter.
(c) Quadrant electrometer.
(d) Moving iron repulsion type ammeter.
(e) Moving iron attraction type voltmeter.
(17) Swamping resistance is used in moving coil instruments to reduce error due to
(a) thermal EMF
(b) temperature
(c) power taken by the instrument
(d) galvanometer sensitivity.
(18) A power factor meter is based on the principle of
(a) electrostatic instrument
(b) Electrodynamometer instrument
(c) Electro thermo type instrument
(d) Rectifier type instrument.
(19) A potentiometer recorder is used for
(a) AC singles
(b) DC signals
(c) both (a) and (b)
(d) time varying signals
(e) none of these.
(20) Transformers used in conjunction with measuring instruments for measuring purposes are called
(a) Measuring transformers
(b) transformer meters
(c) power transformers
(d) instrument transformers
(e) pulse transformers.
(21) Leakage flux in an electrical machine is measure by
(a) Ballistic galvanometer
(b) Flux meter
(c) Either (a) or (b)
(d) Vibration galvanometer
(e) CRO
(22) A C.R.O. is used to indicate
(a) supply waveform
(b) magnitude of the applied voltage
(c) B.H. loop
(d) all of these
(e) Magnitude of the current flowing in it.
(23) An oscillator is a
(a) an amplifier having feedback network
(b) a high gain amplifier
(c) a wide band amplifier
(d) a untuned amplifier
(e) None of these
(24) Distortion can be measured by
(a) Wave meter
(b) Digital filters
(c) Wein bridge circuit
(d) Bridge T filter circuit
(25) Series connected Q- meter is preferable for measurement of components having
(a) high impedance
(b) low impedance
(c) both (a) and (b)
(d) high frequency
(e) low capacitance
(26) A potentiometer is
(a) an active transducer
(b) a passive transducer
(c) a secondary transducer
(d) a digital transducer
(e) a current sensing transducer
(27) The basic components of a digital voltmeter are:
(a) A/D converter and a counter
(b) A/D converted and a rectifier
(c) D/A converter and a counter
(d) Ramp generator and counter
(e) Comparator
(28) Which of the following electrical equipment cannot convert ac into dc
(a) diode
(b) converter
(c) transformer
(d) mercury arc rectifier
(29) Voltage measurement are often taken by using either a voltmeter or
(a) an ammeter
(b) an ohmmeter
(c) an oscillator
(d) a watt-meter
(30)The electric device which blocks DC but allows AC is called:
(a) capacitance
(b) inductor
(c) an oscilloscope
(d) a watt-meter
(31 ) The range of an ammeter can be extended by using a
(a) shunt in series
(b) shunt in parallel
(c) multiplier in series
(d) multiplier in parallel
(32)A device that changes one form of energy to another is called
(a) rheostat
(b) oscillator
(c) transducer
(d) varicap
(33) Aquadag is used in CRO to collect
(a) primary electron
(b) secondary electron
(c) both primary and secondary
(d) none of above
(34) A vertical amplifier for CRO can be designed for
(a) only a high gain
(b) only a broad bandwidth
(c) a constant gain time bandwidth product
(d)all of the above
(35) One of the following is active transducer
(a) Strain gauge
(b) Selsyn
(c) Photovoltic cell
(d) Photo emissive cell
(36) The dynamic characteristics of capacitive transducer are similar to those of
(a) low pass filter
(b) high pass filter
(c) band pass filter
(d) band stop filter
(37) Thermocouples are
(a) passive transducers
(b) active transducers
(c) both active and passive transducers
(d) output transducers
(38) The size of air cored transducers as compare to iron core counter part are
(a) bigger
(b) smaller
(c) same
(39) From the point of view of safety, the resistance of earthing electrode should be:
(a) low
(b) high
(c) medium
(d) the value of resistance of electrode does not effect the safety
(40) In CRT the focusing anode is located
(a) between pre accelerating and accelerating anodes
(b) after accelerating anodes
(c) before pre accelerating anodes
(d) none of above
(41) Which transducer converts heat energy into electrical energy
(a) I. V. D. T.
(b) thermocouple
(c) photoconductor
(d) none of the above
(42) Which of photoelectric transducer is used for production of electric energy by converting solar energy
(a) photo emission cell
(b) photo diode
(c) photo transistor
(d) both (b) and (c)
(43) Which of the following instruments consumes maximum power during measurement?
(a) induction instruments
(b) hot wire instruments
(c) thermocouple instruments
(d) electrodynamometer instruments
(44) Which of the following meters has the best accurancy
(a) moving iron meter
(b) moving coil meter
(c) rectifier type meter
(d) thermocouple meter
(45) The function of the safety resistor in ohm meter is to
(a) limit the current in the coil
(b) increase the voltage drop across the coil
(c) increase the current in the coil
(d) protect the battery
(46) Which of the following instruments is free from hysteresis and eddy current losses?
(a) M.l. instrument
(b) electrostatic instrument
(c) electrodynamometer type instrument
(d)all of these
(47) The dielectric loss of a capacitance can be measured by
(a) Wien bridge
(b) Owen bridge
(c) Schering bridge
(d) Maxwell bridge
(48) Reed frequency meter is essentially a
(a) recording system
(b) deflection measuring system
(c) vibration measuring system
(d) oscillatory measuring system
(49) In measurements made using a Q meter, high impedance elements should preferably be connected in
(a) star
(b) delta
(c) series
(d) parallel
(50) A digital voltmeter measures
(a) peak value
(b) peak-to-peak value
(c) rms value
(d) average value

Test your Instrumentation knowledge: Objective question


1. A balance beam scale uses which of the following units?
a. grams
b .pounds
c. ounces
d. kilograms
2. Which of the following would be about the height of the average doorway?
a. 2 meters
b. 2 centimeters
c. 2 millimeters
d. 2 kilometers
3. A series dissipative regulator is an example of a:
a. linear regulator
b. switching regulator
c. shunt regulator
d. dc-to-dc converter
4. Which of the following is a unit of mass in the metric system?
a. gram
b. milliliter
c. centimeter
d. pounds
5. What device is similar to an RTD but has a negative temperature coefficient?
a. Strain gauge
b. Thermistor
c. Negative-type RTD
d. Thermocouple
6. The resistive change of a strain gauge
a. is based on the weight placed upon it, but can be many thousands of ohms
b. is usually no more than 100 omega.
c. is based on the gauge factor, but is typically less than an ohm
d. has a positive temperature coefficient
Objective Type Questions
Instrumentation System & Devices (IDS)
2
7. The output voltage of a typical thermocouple is
a. Less than 100 mV
b. Greater than 1 V
c. Thermocouples vary resistance, not voltage.
d. None of the above
8. The connections to a thermocouple
a. Can produce an unwanted thermocouple effect, which must be compensated for
b. Produce an extra desirable thermocouple effect
c. Must be protected, since high voltages are present
d. Produce an extra desirable thermocouple effect and must be protected, since high
voltages are present
9. What is the zero-voltage switch used for?
a. To reduce radiation of high frequencies during turn-on of a high current to a load
b. To control low-voltage circuits
c. To provide power to a circuit when power is lost
d. For extremely low-voltage applications
10. Temperature sensing can be achieved by the use of
a. Thermocouples
b. RTDs
c. thermistors
d. All of the above
11. The purpose of compensation for a thermocouple is
a. to decrease temperature sensitivity
b. to increase voltage output
c. to cancel unwanted voltage output of a thermocouple
d. used for high-temperature circuits
12. The change in value of an analog signal during the conversion process produces what is
called the
a. Quantization error
b. Resolution error
c. Nyquist error
d. Sampling error
Objective Type Questions
Instrumentation System & Devices (IDS)
3
13. Which of the following performance specifications applies to a sample-and-hold circuit?
a. Aperture time
b. Aperture droop
c. Feedback
d. Acquisition jitter
14. RTDs are typically connected with other fixed resistors
a. In a pi configuration
b. In a bridge configuration
c. And variable resistors
d. And capacitors in a filter-type circuit
15. Holding current for an SCR is best described as
a. The minimum current required for turn-off
b. The current required before an SCR will turn on
c. The amount of current required to maintain conduction
d. The gate current required maintaining conduction
16. What is the moving part of a linear variable differential transformer?
a. Primary
b. Secondary
c. Diaphragm
d. Core
17. What does a Hall Effect sensor sense?
a. Temperature
b. Moisture
c. Magnetic fields
d. Pressure
18. What causes the piezoelectric effect?
a. Heat or dissimilar metals
b. Pressure on a crystal
c. Water running on iron
d. A magnetic field
Objective Type Questions
Instrumentation System & Devices (IDS)
4
19. What type of application would use a photovoltaic cell?
a. An automobile horn
b. A TI 92 calculator
c. A magnetic field detector
d. A remote power source
20. Which is the seven-segment display?
21. A transducer's function is to:
a. Transmit electrical energy
b. Convert energy
c. Produce mechanical energy
d. Prevent current flow
22. Derived units are obtained from various combinations of
a. Electrical quantities
b. Fundamental units
c. Metric prefixes
d. International standards
23. Scientific notation is a method
a. of expressing a very large number
b. of expressing a very small number
c. used to make calculations with large and small numbers
d. All of the above
24. If you drop a 5 when rounding a number, you are using the
a. round-to-even rule
b. significant digit rule
c. round-off rule
d. retained digit rule
Objective Type Questions
Instrumentation System & Devices (IDS)
5
25. A measure of the repeatability of a measurement of some quantity is
a. error
b. precision
c. accuracy
d. significant
26. Another name for "fundamental units" is
a. base units
b. atoms
c. the metric system
d. letter symbols
27. When using the terms "accuracy" and "precision" for measurements
a. "precision" implies less measurement error than "accuracy"
b. "accuracy" implies less measurement error than "precision"
c. "precision" measures the repeatability of a measurement
d. both terms mean the same thing
28. The difference between scientific and engineering notation is
a. powers of ten representation
b. single vs. multiple digits before decimal point
c. groupings of multiples of three digits
d. All of the above
29. The digits in a measured number that are known to be correct are called
a. accuracy digits
b. significant digits
c. error digits
d. precision digits
30. Pico is what relation to micro?
a. one-tenth
b. one-hundredth
c. one-thousandth
d. one-millionth
Objective Type Questions
Instrumentation System & Devices (IDS)
6
31. Four terminal resistors are used for resistance values
a. Greater than 10 ohm
b. Greater than 1 ohm
c. Less than 1 ohm
d. Of the order of 1M ohm
32. The condition for a resistor to have the same value of resistance at medium frequencies
is as with D.C. is
a. CR ²=L
b. CR ²=2L
c. CR ²=WL
d. CR ²=2WL
33. Permeability is the inverse equivalent of which electrical term?
a. Voltage
b. Current
c. Resistance
d. Conductance
34. What is the flux density of a magnetic field whose flux is 3000 μWb and cross-sectional
area is 0.25 m ²?
a. 12,000 μ T
b. 83,330 μ T
c. 0 μ T
d. More information is needed in order to find flux density.
35. How much flux is there in a magnetic field when its flux density is 5000 mu.gifT and its
cross-sectional area is 300 mm ²?
a. 16.67 m Wb
b. 5.0 μ Wb
c. 3.0 m Wb
d. 1.5 μ Wb
36. What are the effects of moving a closed wire loop through a magnetic field?
a. A voltage is induced in the wire.
b. A current is induced in the wire.
c. The polarity across the wire depends on the direction of motion.
d. All of the above
Objective Type Questions
Instrumentation System & Devices (IDS)
7
37. The Hall Effect
a. is a phenomenon with no practical applications
b. is used in various sensor applications
c. can develop potentials of thousands of volts
d. is the basis for solar cell operation
38. A Hall Effect sensor
a. exists only in theory
b. is a non-contacting magnetic sensor
c. can operate only a few times before failure
d. produces very large voltages
39. Which two values are plotted on a B-H curve graph?
a. Reluctance and flux density
b. Permeability and reluctance
c. Magnetizing force and permeability
d. Flux density and magnetizing force
40. for turbulent flow, the velocity at the center is ____ times the mean velocity
a. 1.2
b. 2.2
c. 2
d. 3.333